E001-Not-Aus

Emergency Switch Fault

❗Possible Cause: The emergency switch is pressed.
Solution: Turn and pull the emergency switch in the indicated direction from the arrow to confirm the emergency stop.

E002-Phasen

Phase Control Light

❗Possible Cause: The phase sequence is incorrect.
✅Solution: Turn the phase sequence around using the phase inverter switch

or

❗Possible Cause: The power supply is faulty.
✅Solution: Check the power supply and if necessary, call a qualified member of staff.

E003-Airsupply

Air Supply Fault

❗Possible Cause: The power supply is faulty.
✅Solution: Check the power supply; consult qualified personnel if necessary.

 

❗Possible Cause: The supply air unit is overheating.
✅Solution: Allow the machine/drive to cool down. Take measures to protect the machine from direct sunlight or excessively high ambient temperatures.

 

❗Possible Cause: The cooling air intake is obstructed.
✅Solution: Check the air filter and clean it if necessary. Ensure there is sufficient clearance between the exhaust port and adjacent components.

 

❗Possible Cause: The belt tension in the supply air unit is outside the tolerance range.
✅Solution: Check the belt tension and adjust if necessary; see the operating instructions.

 

Machine variants with 3x230V power supply

❗Possible Cause: Incorrect setting of the blower selector switch (S10).
✅Solution: Select the blower selector switch according to the number of fans/connections in use.

or

❗Possible Cause: The power supply is faulty.
✅Solution: Check the power supply; consult qualified personnel if necessary.

E004-Airlock

Rotary Airlock Fault

❗Possible Cause: Low ambient temperatures make operating the machine difficult.
✅Solution: Let the machine warm up empty for approx. 10 minutes and if necessary, lubricate the gaskets in the rotary airlock with silicone spray.

or

❗Possible Cause: Foreign objects or pressed insulation material interfere with the rotary airlock.
✅Solution: Check the rotary airlock and clean them if necessary.

 

E005-Shredding

Shredding Shaft Fault

❗Possible Cause: Foreign objects and insulation material disrupt the shredding shafts.
✅Solution: Check the shredding shafts and if necessary, get rid of any foreign objects or insulation material.

E006-Feedgate

Electric Airlock Feed Gate Fault

❗Possible Cause: The airlock feed gate is stiff.
✅Solution: Clean the airlock feed gate’s guide rails.

or

❗Possible Cause: The airlock feed gate is blocked.
✅Solution: Attach the crank tool onto the machine’s attachment and free the airlock feed gate of the blockage by turning the crank tool.